Export limit exceeded: 430281 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (430281 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-27435 2026-04-15 4.2 Medium
Under specific conditions and prerequisites, an unauthenticated attacker could access customer coupon codes exposed in the URL parameters of the Coupon Campaign URL in SAP Commerce. This could allow the attacker to use the disclosed coupon code, hence posing a low impact on confidentiality and integrity of the application.
CVE-2025-27437 2026-04-15 4.3 Medium
A Missing Authorization Check vulnerability exists in the Virus Scanner Interface of SAP NetWeaver Application Server ABAP. Because of this, an attacker authenticated as a non-administrative user can initiate a transaction, allowing them to access but not modify non-sensitive data without further authorization and with no effect on availability.
CVE-2025-29267 2026-04-15 6.5 Medium
SQL Injection vulnerability in Abis, Inc Adjutant Core Accounting ERP build v.PreBeta250F allows a remote attacker to obtain a sensitive information via the cid parameter in the GET request.
CVE-2025-2882 2026-04-15 5.3 Medium
The GreenPay(tm) by Green.Money plugin for WordPress is vulnerable to Sensitive Information Exposure in versions between 3.0.0 and 3.0.9 through the publicly accessible phpinfo.php script. This makes it possible for unauthenticated attackers to view potentially sensitive information contained in the exposed file.
CVE-2025-42974 2026-04-15 4.3 Medium
Due to missing authorization check, an attacker authenticated as a non-administrative user could call a remote-enabled function module. This could enable access to information normally restricted, resulting in low impact on confidentiality. There is no impact on integrity or availability.
CVE-2025-30074 1 Parallels 1 Parallels Desktop 2026-04-15 7.8 High
Alludo Parallels Desktop before 19.4.2 and 20.x before 20.2.2 for macOS on Intel platforms allows privilege escalation to root via the VM creation routine.
CVE-2025-42980 2026-04-15 9.1 Critical
SAP NetWeaver Enterprise Portal Federated Portal Network is vulnerable when a privileged user can upload untrusted or malicious content which, when deserialized, could potentially lead to a compromise of confidentiality, integrity, and availability of the host system.
CVE-2025-31929 2026-04-15 4.2 Medium
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-32406 2026-04-15 8.6 High
An XXE issue in the Director NBR component in NAKIVO Backup & Replication 10.3.x through 11.0.1 before 11.0.2 allows remote attackers fetch and parse the XML response.
CVE-2025-32469 1 Siemens 11 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000re, Ruggedcom Rox Rx1400 and 8 more 2026-04-15 9.9 Critical
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2025-33025 2026-04-15 9.9 Critical
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'traceroute' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2025-3403 2026-04-15 2.7 Low
A vulnerability was found in Vivotek NVR ND8422P, NVR ND9525P and NVR ND9541P 2.4.0.204/3.3.0.104/4.2.0.101. It has been classified as problematic. Affected is an unknown function of the component HTML Form Handler. The manipulation leads to inclusion of sensitive information in source code. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-46963 1 Google 1 Android 2026-04-15 8.1 High
The com.superfast.video.downloader (aka Super Unlimited Video Downloader - All in One) application through 5.1.9 for Android allows an attacker to execute arbitrary JavaScript code via the com.bluesky.browser.ui.BrowserMainActivity component.
CVE-2025-3648 2026-04-15 N/A
A vulnerability has been identified in the Now Platform that could result in data being inferred without authorization. Under certain conditional access control list (ACL) configurations, this vulnerability could enable unauthenticated and authenticated users to use range query requests to infer instance data that is not intended to be accessible to them. To assist customers in enhancing access controls, ServiceNow has introduced additional access control frameworks in Xanadu and Yokohama, such as Query ACLs, Security Data Filters and Deny-Unless ACLs. Additionally, in May 2025, ServiceNow delivered to customers a security update that is designed to enhance customer ACL configurations. Customers, please review the KB Articles in the References section.
CVE-2024-47894 2026-04-15 7.1 High
Kernel software installed and running inside a Guest VM may post improper commands to the GPU Firmware to read data outside the Guest's virtualised GPU memory.
CVE-2025-36640 2 Microsoft, Tenable 2 Windows, Nessus Agent 2026-04-15 8.8 High
A vulnerability has been identified in the installation/uninstallation of the Nessus Agent Tray App on Windows Hosts which could lead to escalation of privileges.
CVE-2025-37102 2026-04-15 7.2 High
An authenticated command injection vulnerability exists in the Command line interface of HPE Networking Instant On Access Points. A successful exploitation could allow a remote attacker with elevated privileges to execute arbitrary commands on the underlying operating system as a highly privileged user.
CVE-2025-37186 2 Hp, Linux 2 Aruba Virtual Intranet Access, Linux 2026-04-15 7.8 High
A local privilege-escalation vulnerability has been discovered in the HPE Aruba Networking Virtual Intranet Access (VIA) client. Successful exploitation of this vulnerability could allow a local attacker to achieve arbitrary code execution with root privileges.
CVE-2025-3916 2026-04-15 N/A
CWE-121: Stack-based Buffer Overflow vulnerability exists that could cause local attackers being able to exploit these issues to potentially execute arbitrary code while the end user opens a malicious project file (SSD file) provided by the attacker.