Export limit exceeded: 23645 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (23645 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-20295 | 1 Cisco | 1 Unified Computing System Manager | 2026-04-15 | 6 Medium |
| A vulnerability in the CLI of Cisco UCS Manager Software could allow an authenticated, local attacker with administrative privileges to read or create a file or overwrite any file on the file system of the underlying operating system of an affected device, including system files. This vulnerability is due to insufficient input validation of command arguments supplied by the user. An attacker could exploit this vulnerability by authenticating to a device and submitting crafted input to the affected command. A successful exploit could allow the attacker to read or create a file or overwrite any file on the file system of the underlying operating system of the affected device, including system files. To exploit this vulnerability, the attacker must have valid administrative credentials on the affected device. | ||||
| CVE-2025-2367 | 2026-04-15 | 6.3 Medium | ||
| A vulnerability has been found in Oiwtech OIW-2431APGN-HP 2.5.3-B20131128 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formScript of the component Personal Script Submenu. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2015-10141 | 2026-04-15 | 5.6 Medium | ||
| An unauthenticated OS command injection vulnerability exists within Xdebug versions 2.5.5 and earlier, a PHP debugging extension developed by Derick Rethans. When remote debugging is enabled, Xdebug listens on port 9000 and accepts debugger protocol commands without authentication. An attacker can send a crafted eval command over this interface to execute arbitrary PHP code, which may invoke system-level functions such as system() or passthru(). This results in full compromise of the host under the privileges of the web server user. | ||||
| CVE-2025-5898 | 1 Gnu | 1 Pspp | 2026-04-15 | 5.3 Medium |
| A vulnerability classified as critical has been found in GNU PSPP 82fb509fb2fedd33e7ac0c46ca99e108bb3bdffb. Affected is the function parse_variables_option of the file utilities/pspp-convert.c. The manipulation leads to out-of-bounds write. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-14500 | 1 Icewarp | 1 Icewarp | 2026-04-15 | N/A |
| IceWarp14 X-File-Operation Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of IceWarp. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of the X-File-Operation header. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-27394. | ||||
| CVE-2025-43984 | 1 Kuwfi | 1 Gc111 | 2026-04-15 | 9.8 Critical |
| An issue was discovered on KuWFi GC111 devices (Hardware Version: CPE-LM321_V3.2, Software Version: GC111-GL-LM321_V3.0_20191211). They are vulnerable to unauthenticated /goform/goform_set_cmd_process requests. A crafted POST request, using the SSID parameter, allows remote attackers to execute arbitrary OS commands with root privileges. | ||||
| CVE-2024-53375 | 1 Tp-link | 1 Archer Axe75 Firmware | 2026-04-15 | 8 High |
| An Authenticated Remote Code Execution (RCE) vulnerability affects the TP-Link Archer router series. A vulnerability exists in the "tmp_get_sites" function of the HomeShield functionality provided by TP-Link. This vulnerability is still exploitable without the activation of the HomeShield functionality. | ||||
| CVE-2011-10007 | 1 Redhat | 3 Enterprise Linux, Rhel Els, Rhel Eus | 2026-04-15 | 8.8 High |
| File::Find::Rule through 0.34 for Perl is vulnerable to Arbitrary Code Execution when `grep()` encounters a crafted filename. A file handle is opened with the 2 argument form of `open()` allowing an attacker controlled filename to provide the MODE parameter to `open()`, turning the filename into a command to be executed. Example: $ mkdir /tmp/poc; echo > "/tmp/poc/|id" $ perl -MFile::Find::Rule \ -E 'File::Find::Rule->grep("foo")->in("/tmp/poc")' uid=1000(user) gid=1000(user) groups=1000(user),100(users) | ||||
| CVE-2011-10017 | 1 Snort | 1 Snort | 2026-04-15 | N/A |
| Snort Report versions < 1.3.2 contains a remote command execution vulnerability in the nmap.php and nbtscan.php scripts. These scripts fail to properly sanitize user input passed via the target GET parameter, allowing attackers to inject arbitrary shell commands. Exploitation requires no authentication and can result in full compromise of the underlying system. | ||||
| CVE-2012-10059 | 1 Dolibarr | 2 Dolibarr, Dolibarr Erp/crm | 2026-04-15 | N/A |
| Dolibarr ERP/CRM versions <= 3.1.1 and <= 3.2.0 contain a post-authenticated OS command injection vulnerability in its database backup feature. The export.php script fails to sanitize the sql_compat parameter, allowing authenticated users to inject arbitrary system commands, resulting in remote code execution on the server. | ||||
| CVE-2021-33633 | 2026-04-15 | 7.3 High | ||
| Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in openEuler aops-ceres on Linux allows Command Injection. This vulnerability is associated with program files ceres/function/util.Py. This issue affects aops-ceres: from 1.3.0 through 1.4.1. | ||||
| CVE-2024-43656 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43657 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2023-34873 | 2026-04-15 | N/A | ||
| On MOBOTIX P3 cameras before MX-V4.7.2.18 and Mx6 cameras before MX-V5.2.0.61, the tcpdump feature does not properly validate input, which allows authenticated users to execute code. | ||||
| CVE-2024-43654 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43652 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. | ||||
| CVE-2024-43651 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). | ||||
| CVE-2023-53872 | 1 Wp2fac | 1 Wp2fac | 2026-04-15 | N/A |
| Wp2Fac 1.0 contains an OS command injection vulnerability in the send.php endpoint that allows remote attackers to execute arbitrary system commands. Attackers can inject shell commands through the 'numara' parameter by appending shell commands with '&' operators to execute malicious code. | ||||
| CVE-2021-46772 | 2026-04-15 | 3.9 Low | ||
| Insufficient input validation in the ABL may allow a privileged attacker with access to the BIOS menu or UEFI shell to tamper with the structure headers in SPI ROM causing an out of bounds memory read and write, potentially resulting in memory corruption or denial of service. | ||||