Search Results (23644 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-11964 2 Microsoft, Tcpdump 2 Windows, Libpcap 2026-04-15 1.9 Low
On Windows only, if libpcap needs to convert a Windows error message to UTF-8 and the message includes characters that UTF-8 represents using 4 bytes, utf_16le_to_utf_8_truncated() can write data beyond the end of the provided buffer.
CVE-2025-34095 2026-04-15 N/A
An OS command injection vulnerability exists in Mako Server versions 2.5 and 2.6, specifically within the tutorial interface provided by the examples/save.lsp endpoint. An unauthenticated attacker can send a crafted PUT request containing arbitrary Lua os.execute() code, which is then persisted on disk and triggered via a subsequent GET request to examples/manage.lsp. This allows remote command execution on the underlying operating system, impacting both Windows and Unix-based deployments.
CVE-2025-52994 1 Phpthumb Project 1 Phpthumb 2026-04-15 4.9 Medium
gif_outputAsJpeg in phpThumb through 1.7.23 allows phpthumb.gif.php OS Command Injection via a crafted parameter value. This is fixed in 1.7.23-202506081709.
CVE-2025-68459 1 Ruijie 3 Ap180, Ap180-ac, Ap180-pe 2026-04-15 7.2 High
RG - AP180, Indoor Wall Plate Wireless AP AP180 series provided by Ruijie Networks Co., Ltd. contain an OS command injection vulnerability. An arbitrary OS command may be executed on the product by an attacker who logs in to the CLI service.
CVE-2025-27078 2026-04-15 6.5 Medium
A vulnerability in a system binary of AOS-8 Instant and AOS-10 AP could allow an authenticated remote attacker to inject commands into the underlying operating system while using the CLI. Successful exploitation could lead to complete system compromise.
CVE-2025-43875 1 Johnsoncontrols 5 Istar Edge G2, Istar Ultra, Istar Ultra G2 and 2 more 2026-04-15 N/A
Under certain circumstances a successful exploitation could result in access to the device.
CVE-2025-59728 1 Ffmpeg 1 Ffmpeg 2026-04-15 6.5 Medium
When calculating the content path in handling of MPEG-DASH manifests, there's an out-of-bounds NUL-byte write one byte past the end of the buffer.When we call xmlNodeGetContent below [0], it returns a buffer precisely allocated to match the string length, using strdup internally. If this buffer is not an empty string, it is assigned to root_url at [1].If the last (non-NUL) byte in this buffer is not '/' then we append '/' in-place at [2]. This will write two bytes into the buffer, starting at the last valid byte in the buffer, writing the NUL byte beyond the end of the allocated buffer. We recommend upgrading to version 8.0 or beyond.
CVE-2013-3307 1 Linksys 2 E1000, E1200 2026-04-15 8.3 High
Linksys E1000 devices through 2.1.02, E1200 devices before 2.0.05, and E3200 devices through 1.0.04 allow OS command injection via shell metacharacters in the apply.cgi ping_ip parameter on TCP port 52000.
CVE-2025-11546 2 Linux, Nec 5 Linux, Clusterpro X, Clusterpro X Singleserversafe and 2 more 2026-04-15 N/A
CLUSTERPRO X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 and EXPRESSCLUSTER X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, CLUSTERPRO X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, EXPRESSCLUSTER X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 allows an attacker sends specially crafted network packets to the product, arbitrary OS commands may be executed without authentication.
CVE-2025-10239 1 Progress 1 Flowmon 2026-04-15 7.2 High
In Flowmon versions prior to 12.5.5, a vulnerability has been identified that allows a user with administrator privileges and access to the management interface to execute additional unintended commands within scripts intended for troubleshooting purposes.
CVE-2023-5912 1 Lenovo 1 Notebook 2026-04-15 6.7 Medium
A potential memory leakage vulnerability was reported in some Lenovo Notebook products that may allow a local attacker with elevated privileges to write to NVRAM variables.
CVE-2024-10653 1 Changingtec 1 Idexpert 2026-04-15 7.2 High
IDExpert from CHANGING Information Technology does not properly validate a specific parameter in the administrator interface, allowing remote attackers with administrative privileges to inject and execute OS commands on the server.
CVE-2022-20845 2026-04-15 6 Medium
A vulnerability in the TL1 function of Cisco Network Convergence System (NCS) 4000 Series could allow an authenticated, local attacker to cause a memory leak in the TL1 process. This vulnerability is due to TL1 not freeing memory under some conditions. An attacker could exploit this vulnerability by connecting to the device and issuing TL1 commands after being authenticated. A successful exploit could allow the attacker to cause the TL1 process to consume large amounts of memory. When the memory reaches a threshold, the Resource Monitor (Resmon) process will begin to restart or shutdown the top five consumers of memory, resulting in a denial of service (DoS).Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability.This advisory is part of the September 2022 release of the Cisco IOS XR Software Security Advisory Bundled Publication. For a complete list of the advisories and links to them, see .
CVE-2024-10573 1 Redhat 1 Enterprise Linux 2026-04-15 6.7 Medium
An out-of-bounds write flaw was found in mpg123 when handling crafted streams. When decoding PCM, the libmpg123 may write past the end of a heap-located buffer. Consequently, heap corruption may happen, and arbitrary code execution is not discarded. The complexity required to exploit this flaw is considered high as the payload must be validated by the MPEG decoder and the PCM synth before execution. Additionally, to successfully execute the attack, the user must scan through the stream, making web live stream content (such as web radios) a very unlikely attack vector.
CVE-2024-11345 2026-04-15 7.3 High
A heap-based memory vulnerability has been identified in the Postscript interpreter in various Lexmark devices. The vulnerability can be leveraged by an attacker to execute arbitrary code.
CVE-2024-10118 1 Secom 1 Wrtr-304gn-304tw-upsc Firmware 2026-04-15 9.8 Critical
SECOM WRTR-304GN-304TW-UPSC does not properly filter user input in the specific functionality. Unauthenticated remote attackers can exploit this vulnerability to inject and execute arbitrary system commands on the device.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2023-49675 2026-04-15 7.8 High
An unauthenticated local attacker may trick a user to open corrupted project files to execute arbitrary code or crash the system due to an out-of-bounds write vulnerability.
CVE-2023-49614 2026-04-15 5.7 Medium
Out of bounds write in firmware for some Intel(R) FPGA products before version 2.9.0 may allow escalation of privilege and information disclosure.