| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| macrozheng mall-tiny 1.0.1 is vulnerable to Incorrect Access Control. The project imports users by default, and the test user is made a super administrator. |
| SAP Disclosure Management - version 10.1, allows an authenticated attacker to exploit certain misconfigured application endpoints to read sensitive data. These endpoints are normally exposed over the network and successful exploitation can lead to the exposure of data like financial reports. |
| Vulnerability in the Oracle CRM Technical Foundation product of Oracle E-Business Suite (component: Preferences). Supported versions that are affected are 12.2.3-12.2.14. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle CRM Technical Foundation. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Oracle CRM Technical Foundation, attacks may significantly impact additional products (scope change). Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of Oracle CRM Technical Foundation accessible data as well as unauthorized read access to a subset of Oracle CRM Technical Foundation accessible data. CVSS 3.1 Base Score 6.1 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). |
| Dart SDK contains the HTTPClient in dart:io library whcih includes authorization headers when handling cross origin redirects. These headers may be explicitly set and contain sensitive information. By default, HttpClient handles redirection logic. If a request is sent to example.com with authorization header and it redirects to an attackers site, they might not expect attacker site to receive authorization header. We recommend updating the Dart SDK to version 2.16.0 or beyond. |
| When adding a private file via the editor in Drupal 8.2.x before 8.2.7, the editor will not correctly check access for the file being attached, resulting in an access bypass. |
| In Odoo 8.0, Odoo Community Edition 9.0 and 10.0, and Odoo Enterprise Edition 9.0 and 10.0, incorrect access control on OAuth tokens in the OAuth module allows remote authenticated users to hijack OAuth sessions of other users. |
| 389 Directory Server before 1.3.3.10 allows attackers to bypass intended access restrictions and modify directory entries via a crafted ldapmodrdn call. |
| On Juniper Networks Junos Space versions prior to 16.1R1, due to an insufficient authorization check, readonly users on the Junos Space administrative web interface can execute code on the device. |
| Warsaw Huawei Smart phones with software of versions earlier than Warsaw-AL00C00B180, versions earlier than Warsaw-TL10C01B180 have a permission control vulnerability. Due to improper authorization on specific processes, an attacker with the root privilege of a mobile Android system can exploit this vulnerability to obtain some information of the user. |
| FusionSphere V100R006C00SPC102(NFV) has an incorrect authorization vulnerability. An authenticated attacker could execute commands that he/she should have had no permission to perform, thereby querying, modifying, and deleting certain service data and making the service unavailable. |
| On Juniper Networks Junos Space versions prior to 16.1R1, due to an insufficient authorization check, readonly users on the Junos Space administrative web interface can create privileged users, allowing privilege escalation. |
| The move_pages system call in mm/migrate.c in the Linux kernel before 4.12.9 doesn't check the effective uid of the target process, enabling a local attacker to learn the memory layout of a setuid executable despite ASLR. |
| FusionSphere OpenStack V100R006C00 has an improper authorization vulnerability. Due to improper authorization, an attacker with low privilege may exploit this vulnerability to obtain the operation authority of some specific directory, causing privilege escalation. |
| An Improper Authorization issue was discovered in OSIsoft PI Integrator for Business Analytics before 2016 R2, PI Integrator for Microsoft Azure before 2016 R2 SP1, and PI Integrator for SAP HANA before 2017. An attacker is able to gain privileged access to the system while unauthorized. |
| An error in the implementation of an autosubscribe feature in the check_stream_exists route of the Zulip group chat application server before 1.4.3 allowed an authenticated user to subscribe to a private stream that should have required an invitation from an existing member to join. The issue affects all previously released versions of the Zulip server. |
| Red Hat 3scale (aka RH-3scale) API Management Platform (AMP) before 2.0.0 would permit creation of an access token without a client secret. An attacker could use this flaw to circumvent authentication controls and gain access to restricted APIs. NOTE: some sources have a typo in which CVE-2017-7512 maps to an OpenVPN vulnerability. The proper CVE ID for that OpenVPN vulnerability is CVE-2017-7521. Specifically, CVE-2017-7521 is the correct CVE ID for TWO closely related findings in OpenVPN. Any source that lists BOTH CVE-2017-7512 and CVE-2017-7521 for OpenVPN should have listed ONLY CVE-2017-7521. |
| In Zulip Server before 1.7.1, on a server with multiple realms, a vulnerability in the invitation system lets an authorized user of one realm on the server create a user account on any other realm. |
| An issue was discovered in network-manager-applet (aka network-manager-gnome) in Ubuntu 12.04 LTS, 14.04 LTS, 16.04 LTS, and 16.10. A local attacker could use this issue at the default Ubuntu login screen to access local files and execute arbitrary commands as the lightdm user. The exploitation requires physical access to the locked computer and the Wi-Fi must be turned on. An access point that lets you use a certificate to login is required as well, but it's easy to create one. Then, it's possible to open a nautilus window and browse directories. One also can open some applications such as Firefox, which is useful for downloading malicious binaries. |
| An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer account, allows changing very sensitive parameters. NOTE: the vendor reports that Grid Guard is not an authentication feature; it is only a tracing feature. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| GNU screen before 4.5.1 allows local users to modify arbitrary files and consequently gain root privileges by leveraging improper checking of logfile permissions. |