| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| iMonitor EAM 9.6394 transmits communication between the EAM client agent and the EAM server, as well as between the EAM monitor management software and the server, in plaintext without authentication or encryption. An attacker with network access can intercept sensitive information (such as credentials, keylogger data, and personally identifiable information) and tamper with traffic. This allows both unauthorized disclosure and modification of data, including issuing arbitrary commands to client agents. |
| Secure flag not set and SameSIte was set to Lax in the Foreseer Reporting Software (FRS). Absence of this secure flag could lead into the session cookie being transmitted over unencrypted HTTP connections. This security issue has been resolved in the latest version of FRS v1.5.100. |
| The Pixmeo Osirix MD Web Portal sends credential information without encryption, which could allow an attacker to steal credentials. |
| Cleartext transmission of sensitive information issue exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a man-in-the-middle attack may allow a remote unauthenticated attacker to eavesdrop the communication and obtain the authentication information. |
| Due to an unsecure default configuration HTTP is used instead of HTTPS for the web interface. An unauthenticated attacker on the same network could exploit this to learn sensitive data during transmission. |
| A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI. |
| Ecovacs Deebot T10 1.7.2 transmits Wi-Fi credentials in cleartext during the pairing process. |
| An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure. |
| Aikaan IoT management platform v3.25.0325-5-g2e9c59796 sends a newly generated password to users in plaintext via email and also includes the same password as a query parameter in the account activation URL (e.g., https://domain.com/activate=xyz). This practice can result in password exposure via browser history, proxy logs, referrer headers, and email caching. The vulnerability impacts user credential confidentiality during initial onboarding. |
| DuraComm SPM-500 DP-10iN-100-MU
transmits sensitive data without encryption over a channel that could be intercepted by attackers. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to cleartext transmission of credentials in its web management interface. A remote attacker could exploit this vulnerability by intercepting the network traffic and capturing cleartext credentials.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a proprietary protocol on TCP port 1069 to perform management operations
such as modifying system properties. The user management functionality
handles sensitive data such as registered usernames and passwords over
an unencrypted channel, allowing an adjacent attacker to intercept valid
credentials to gain access to the device. |
| TM2 Monitoring v3.04 contains an authentication bypass and plaintext credential disclosure. |
| An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials. |
| General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow
an attacker to observe network traffic to obtain sensitive information,
including plaintext credentials. |
| A flaw was found in the ansible automation platform. An insecure WebSocket connection was being used in installation from the Ansible rulebook EDA server. An attacker that has access to any machine in the CIDR block could download all rulebook data from the WebSocket, resulting in loss of confidentiality and integrity of the system. |
| Johan Fagerström, member of the AXIS OS Bug Bounty Program, has found that a O3C feature may expose sensitive traffic between the client (Axis device) and (O3C) server. If O3C is not being used this flaw does not apply.
Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution. |
| Missing authentication for critical function in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network. |
| Cleartext transmission of sensitive information in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network. |
| A flaw was found in rhn-proxy. This vulnerability may allow the rhn-proxy to transmit user credentials in clear-text when it accesses RHN Satellite. This could lead to information disclosure, where sensitive authentication details are exposed to unauthorized parties. |