| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Deserialization of Untrusted Data vulnerability in Cozmoslabs TranslatePress translatepress-multilingual allows Object Injection.This issue affects TranslatePress: from n/a through <= 2.10.2. |
| Deserialization of Untrusted Data vulnerability in sbouey Falang multilanguage falang allows Object Injection.This issue affects Falang multilanguage: from n/a through <= 1.3.65. |
| Kafbat UI is a web user interface for managing Apache Kafka clusters. An unsafe deserialization vulnerability in version 1.0.0 allows any unauthenticated user to execute arbitrary code on the server. Version 1.1.0 fixes the issue. |
| Deserialization of Untrusted Data vulnerability in CRM Perks WP Gravity Forms Keap/Infusionsoft gf-infusionsoft allows Object Injection.This issue affects WP Gravity Forms Keap/Infusionsoft: from n/a through <= 1.2.3. |
| Deserialization of Untrusted Data vulnerability in uxper Togo togo.This issue affects Togo: from n/a through < 1.0.4. |
| Deserialization of Untrusted Data vulnerability in wpshuffle Subscribe to Download subscribe-to-download allows Object Injection.This issue affects Subscribe to Download: from n/a through <= 2.0.9. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| Deserialization of Untrusted Data vulnerability in captivateaudio Captivate Sync captivatesync-trade allows Object Injection.This issue affects Captivate Sync: from n/a through <= 3.0.3. |
| A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. |
| PowSyBl (Power System Blocks) is a framework to build power system oriented software. In versions 6.3.0 to 6.7.1, there is a deserialization issue in the read method of the SparseMatrix class that can lead to a wide range of privilege escalations depending on the circumstances. This method takes in an InputStream and returns a SparseMatrix object. This issue has been patched in com.powsybl:powsybl-math: 6.7.2. A workaround for this issue involves not using SparseMatrix deserialization (SparseMatrix.read(...) methods). |
| Deserialization of Untrusted Data vulnerability in Tijmen Smit WP Store Locator wp-store-locator allows Object Injection.This issue affects WP Store Locator: from n/a through <= 2.2.260. |
| Deserialization of Untrusted Data vulnerability in Hernan Villanueva Boldermail boldermail allows Object Injection.This issue affects Boldermail: from n/a through <= 2.4.0. |
| Deserialization of Untrusted Data vulnerability in BoldThemes Addison addison allows Object Injection.This issue affects Addison: from n/a through < 1.4.8. |
| A vulnerability has been identified in SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. |
| A vulnerability was found in BeamCtrl Airiana up to 11.0. It has been declared as problematic. This vulnerability affects unknown code of the file coef. The manipulation leads to deserialization. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. |
| NewPipe is an Android app for video streaming written in Java. It supports exporting and importing backups, as a way to let users move their data to a new device effortlessly. However, in versions 0.13.4 through 0.26.1, importing a backup file from an untrusted source could have resulted in Arbitrary Code Execution. This is because backups are serialized/deserialized using Java's Object Serialization Stream Protocol, which can allow constructing any class in the app, unless properly restricted.
To exploit this vulnerability, an attacker would need to build a backup file containing the exploit, and then persuade a user into importing it. During the import process, the malicious code would be executed, possibly crashing the app, stealing user data from the NewPipe app, performing nasty actions through Android APIs, and attempting Android JVM/Sandbox escapes through vulnerabilities in the Android OS.
The attack can take place only if the user imports a malicious backup file, so an attacker would need to trick a user into importing a backup file from a source they can control. The implementation details of the malicious backup file can be independent of the attacked user or the device they are being run on, and do not require additional privileges.
All NewPipe versions from 0.13.4 to 0.26.1 are vulnerable. NewPipe version 0.27.0 fixes the issue by doing the following: Restrict the classes that can be deserialized when calling Java's Object Serialization Stream Protocol, by adding a whitelist with only innocuous data-only classes that can't lead to Arbitrary Code Execution; deprecate backups serialized with Java's Object Serialization Stream Protocol; use JSON serialization for all newly created backups (but still include an alternative file serialized with Java's Object Serialization Stream Protocol in the backup zip for backwards compatibility); show a warning to the user when attempting to import a backup where the only available serialization mode is Java's Object Serialization Stream Protocol (note that in the future this serialization mode will be removed completely).
|
| A local privilege escalation vulnerability in Sophos Intercept X for Windows with Central Device Encryption 2024.2.0 and older allows writing of arbitrary files. |
| A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. |