| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Software installed and run as a non-privileged user may conduct improper GPU system calls to gain access to the graphics buffers of a parent process. |
| Software installed and run as a non-privileged user may conduct improper GPU system calls to achieve unauthorised reads and writes of physical memory from the GPU HW. |
| Software installed and run as a non-privileged user may conduct improper GPU system calls to allow unprivileged access to arbitrary physical memory page. |
| Software installed and run as a non-privileged user may conduct GPU system calls to read and write freed physical memory from the GPU. |
| Inclusion of Functionality from Untrusted Control Sphere(CWE-829) in the Command Centre Server and Workstations may allow an attacker to perform Remote Code Execution (RCE).
This issue affects: Command Centre Server and Command Centre Workstations 9.10 prior to vEL9.10.1530 (MR2), 9.00 prior to vEL9.00.2168 (MR4), 8.90 prior to vEL8.90.2155 (MR5), 8.80 prior to vEL8.80.1938 (MR6), all versions of 8.70 and prior. |
| cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring. |
| Software installed and run as a non-privileged user can trigger the GPU kernel driver to write to arbitrary read-only system files that have been mapped into application memory. |
| A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices do not properly handle TCP packets with an incorrect structure. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the network cable of the device needs to be unplugged and re-plugged. |
| OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent attacker with credentials to execute arbitrary OS commands by sending a specially crafted request to the product. |
| A Information Exposure Vulnerability has been found on Meta4 HR. This vulnerability allows an attacker to obtain a lot of information about the application such as the variables set in the process, the Tomcat versions, library versions and underlying operation system via HTTP GET '/sitetest/english/dumpenv.jsp'. |
| ReCrystallize Server 5.10.0.0 uses a authorization mechanism that relies on the value of a cookie, but it does not bind the cookie value to a session ID. Attackers can easily modify the cookie value, within a browser or by implementing client-side code outside of a browser. Attackers can bypass the authentication mechanism by modifying the cookie to contain an expected value. |
| The configuration pages available are not intended to be placed on an Internet facing web server, as they expose file paths to the client, who can be an attacker. Instead of rewriting these pages to avoid this vulnerability, they will be dismissed from future releases of Cegid Meta4 HR, as they do not offer product functionality |
| An issue in the HistoryQosPolicy component of FastDDS v2.12.x, v2.11.x, v2.10.x, and v2.6.x leads to a SIGABRT (signal abort) upon receiving DataWriter's data. |
| An Uncontrolled Search Path Element vulnerability in B&R Industrial Automation Scene Viewer, B&R Industrial Automation Automation Runtime, B&R Industrial Automation mapp Vision, B&R Industrial Automation mapp View, B&R Industrial Automation mapp Cockpit, B&R Industrial Automation mapp Safety, B&R Industrial Automation VC4, B&R Industrial Automation APROL, B&R Industrial Automation CAN Driver, B&R Industrial Automation CAN Driver CC770, B&R Industrial Automation CAN Driver SJA1000, B&R Industrial Automation Tou0ch Lock, B&R Industrial Automation B&R Single-Touch Driver, B&R Industrial Automation Serial User Mode Touch Driver, B&R Industrial Automation Windows Settings Changer (LTSC), B&R Industrial Automation Windows Settings Changer (2019 LTSC), B&R Industrial Automation Windows 10 Recovery Solution, B&R Industrial Automation ADI driver universal, B&R Industrial Automation ADI Development Kit, B&R Industrial Automation ADI .NET SDK, B&R Industrial Automation SRAM driver, B&R Industrial Automation HMI Service Center, B&R Industrial Automation HMI Service Center Maintenance, B&R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0. |
| NVIDIA Merlin Transformers4Rec for Linux contains a vulnerability in the Trainer component, where a user could cause a deserialization issue. A successful exploit of this vulnerability might lead to code execution, denial of service, information disclosure, and data tampering. |
| The Link Whisper Free plugin for WordPress is vulnerable to PHP Object Injection in all versions up to, and including, 0.7.1 via deserialization of untrusted input of the 'mfn-page-items' post meta value. This makes it possible for authenticated attackers, with contributor-level access and above, to inject a PHP Object. No known POP chain is present in the vulnerable plugin. If a POP chain is present via an additional plugin or theme installed on the target system, it could allow the attacker to delete arbitrary files, retrieve sensitive data, or execute code. |
| The com.videodownload.browser.videodownloader (aka AppTool-Browser-Video All Video Downloader) application 20-30.05.24 for Android allows an attacker to execute arbitrary JavaScript code via the acr.browser.lightning.DefaultBrowserActivity component. |
| A Local privilege escalation vulnerability found in a Self-Hosted UniFi Network Server with UniFi Network Application (Version 8.4.62 and earlier) allows a malicious actor with a local operational system user to execute high privilege actions on UniFi Network Server. |
| An issue was discovered in Atos Eviden SMC xScale before 1.6.6. During initialization of nodes, some configuration parameters are retrieved from management nodes. These parameters embed credentials whose integrity and confidentiality may be important to the security of the HPC configuration. Because these parameters are needed for initialization, there is no available mechanism to ensure access control on the management node, and a mitigation measure is normally put in place to prevent access to unprivileged users. It was discovered that this mitigation measure does not survive a reboot of diskful nodes. (Diskless nodes are not at risk.) The mistake lies in the cloudinit configuration: the iptables configuration should have been in the bootcmd instead of the runcmd section. |
| The Spotify app 8.9.58 for iOS has a buffer overflow in its use of strcat. |