Search Results (1890 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-54546 1 Arista 1 Danz Monitoring Fabric 2026-04-15 7.5 High
On affected platforms, restricted users could use SSH port forwarding to access host-internal services
CVE-2024-22029 2026-04-15 7.8 High
Insecure permissions in the packaging of tomcat allow local users that win a race during package installation to escalate to root
CVE-2025-53396 2026-04-15 N/A
Incorrect permission assignment for critical resource issue exists in SS1 Ver.16.0.0.10 and earlier (Media version:16.0.0a and earlier), which may allow users who can log in to a client terminal to obtain root privileges.
CVE-2021-47742 1 Epicgames 1 Psionix Rocket League 2026-04-15 8.8 High
Epic Games Psyonix Rocket League <=1.95 contains an insecure permissions vulnerability that allows authenticated users to modify executable files with full access permissions. Attackers can leverage the 'F' (Full) flag for the 'Authenticated Users' group to change executable files and potentially escalate system privileges.
CVE-2024-6619 2 Aveva, Ocean Data Systems 2 Reports For Operations 2023, Dream Report 2023 2026-04-15 N/A
In Ocean Data Systems Dream Report, an incorrect permission vulnerability could allow a local unprivileged attacker to escalate their privileges and could cause a denial-of-service.
CVE-2024-38456 1 Vivavis 1 High-leit 2026-04-15 7.8 High
HIGH-LEIT V05.08.01.03 and HIGH-LEIT V04.25.00.00 to 4.25.01.01 for Windows from Vivavis contain an insecure file and folder permissions vulnerability in prunsrv.exe. A regular user (non-admin) can exploit the weak folder and file permissions to escalate privileges and execute arbitrary code in the context of NT AUTHORITY\SYSTEM.
CVE-2025-54497 1 Cognex 2 In-sight Camera Firmware, In-sight Explorer 2026-04-15 8.1 High
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke the SetSerialPort functionality to modify relevant device properties (such as serial interface settings), contradicting the security model proposed in the user manual.
CVE-2024-1486 2026-04-15 7.4 High
Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices
CVE-2025-14988 1 Iba Systems 1 Ibapda 2026-04-15 N/A
A security issue has been identified in ibaPDA that could allow unauthorized actions on the file system under certain conditions. This may impact the confidentiality, integrity, or availability of the system.
CVE-2025-68462 1 Debian 1 Freedombox 2026-04-15 3.2 Low
Freedombox before 25.17.1 does not set proper permissions for the backups-data directory, allowing the reading of dump files of databases.
CVE-2023-5936 2026-04-15 7.8 High
On Unix systems (Linux, MacOS), Arc uses a temporary file with unsafe privileges. By tampering with such file, a malicious local user in the system may be able to trigger arbitrary code execution with root privileges.
CVE-2024-42449 1 Veeam 1 Service Provider Console 2026-04-15 N/A
From the VSPC management agent machine, under condition that the management agent is authorized on the server, it is possible to remove arbitrary files on the VSPC server machine.
CVE-2024-41970 2026-04-15 5.7 Medium
A low privileged remote attacker may gain access to forbidden diagnostic data due to incorrect permission assignment for critical resources.
CVE-2025-0758 1 Hitachi 1 Vantara Pentaho Business Analytics Server 2026-04-15 6.1 Medium
Overview  The product specifies permissions for a security-critical resource in a way that allows that resource to be read or modified by unintended actors. (CWE-732)  Description  Hitachi Vantara Pentaho Business Analytics Server prior to versions 10.2.0.2, including 9.3.x and 8.3.x, is installed with Karaf JMX beans enabled and accessible by default.  Impact  When the vulnerability is leveraged, a user with local execution privileges can access functionality exposed by Karaf beans contained in the product.
CVE-2024-39967 2026-04-15 6.5 Medium
Insecure permissions in Aginode GigaSwitch v5 allows attackers to access sensitive information via using the SCP command.
CVE-2024-50590 1 Hasomed 1 Elefant 2026-04-15 7.8 High
Attackers with local access to the medical office computer can escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is writable for all users. In addition, the Elefant installer registers two Firebird database services which are running as “NT AUTHORITY\SYSTEM”.  Path: C:\Elefant1\Firebird_2\bin\fbserver.exe Path: C:\Elefant1\Firebird_2\bin\fbguard.exe Both service binaries are user writable. This means that a local attacker can rename one of the service binaries, replace the service executable with a new executable, and then restart the system. Once the system has rebooted, the new service binary is executed as "NT AUTHORITY\SYSTEM".
CVE-2024-44729 1 Mirotalk 1 Mirotalk P2p 2026-04-15 7.5 High
Incorrect access control in the component app/src/server.js of Mirotalk before commit 9de226 allows unauthenticated attackers without presenter privileges to arbitrarily eject users from a meeting.
CVE-2024-27108 2026-04-15 6.8 Medium
Non privileged access to critical file vulnerability in GE HealthCare EchoPAC products
CVE-2025-35999 1 Intel 1 System Firmware Update Utility (sysfwupdt) For Intel(r) Server Boards And Intel(r) Server Systems Based 2026-04-15 6.7 Medium
Incorrect permission assignment for critical resource for some System Firmware Update Utility (SysFwUpdt) for Intel(R) Server Boards and Intel(R) Server Systems Based before version 16.0.12. within Ring 3: User Applications may allow an escalation of privilege. System software adversary with a privileged user combined with a low complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires passive user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2024-12564 2026-04-15 N/A
Exposure of Sensitive Information to an Unauthorized Actor vulnerability was discovered in Open Design Alliance CDE inWEB SDK before 2025.3. Installing CDE Server with default settings allows unauthorized users to visit prometheus metrics page. This can allow attackers to understand more things about the target application which may help in further investigation and exploitation.