| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in sysPass 2.x before 2.1, in which an algorithm was never sufficiently reviewed by cryptographers. The fact that inc/SP/Core/Crypt.class is using the MCRYPT_RIJNDAEL_256() function (the 256-bit block version of Rijndael, not AES) instead of MCRYPT_RIJNDAEL_128 (real AES) could help an attacker to create unknown havoc in the remote system. |
| IBM AppScan Source uses a one-way hash without salt to encrypt highly sensitive information, which could allow a local attacker to decrypt information more easily. |
| Apache OpenMeetings 1.0.0 uses not very strong cryptographic storage, captcha is not used in registration and forget password dialogs and auth forms missing brute force protection. |
| Dolibarr ERP/CRM 4.0.4 stores passwords with the MD5 algorithm, which makes brute-force attacks easier. |
| A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands. |
| go-jose before 1.0.4 suffers from an invalid curve attack for the ECDH-ES algorithm. When deriving a shared key using ECDH-ES for an encrypted message, go-jose neglected to check that the received public key on a message is on the same curve as the static private key of the receiver, thus making it vulnerable to an invalid curve attack. |
| On Samsung NVR devices, remote attackers can read the MD5 password hash of the 'admin' account via certain szUserName JSON data to cgi-bin/main-cgi, and login to the device with that hash in the szUserPasswd parameter. |
| A vulnerability in Trend Micro ScanMail for Exchange 12.0 exists in which some communications to the update servers are not encrypted. |
| The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE. |
| In specific scenarios, on Windows the operator credentials may be encrypted in a manner that is not completely machine-dependent.
|
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 uses the MD5 algorithm to hash the passwords before storing them but does not salt the hash. As a result, attackers may be able to crack the hashed passwords. |
| Inadequate encryption may allow the passwords for Emerson OpenEnterprise versions through 3.3.4 user accounts to be obtained. |
| An attacker could decipher the encryption and gain access to MDT AutoSave versions prior to v6.02.06. |
| Inadequate encryption may allow the credentials used by Emerson OpenEnterprise, up through version 3.3.5, to access field devices and external systems to be obtained. |
| Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all versions of XGR-CPUH prior to V1.80, all versions of XGB-XBMS prior to V3.00, all versions of XGB-XBCH prior to V1.90, and all versions of XGB-XECH prior to V1.30. This would allow an attacker to identify and decrypt the password of the affected PLCs by sniffing the PLC’s communication traffic. |
| The Config-files of Horner Automation’s RCC 972 with firmware version 15.40 are encrypted with weak XOR encryption vulnerable to reverse engineering. This could allow an attacker to obtain credentials to run services such as File Transfer Protocol (FTP) and Hypertext Transfer Protocol (HTTP). |
| IO FinNet tss-lib before 2.0.0 allows a collision of hash values. |
| Huawei AR routers with software before V200R007C00SPC100; Quidway S9300 routers with software before V200R009C00; S12700 routers with software before V200R008C00SPC500; S9300, Quidway S5300, and S5300 routers with software before V200R007C00; and S5700 routers with software before V200R007C00SPC500 make it easier for remote authenticated administrators to obtain and decrypt passwords by leveraging selection of a reversible encryption algorithm. |
| Huawei AR routers with software before V200R007C00SPC100; Quidway S9300 routers with software before V200R009C00; S12700 routers with software before V200R008C00SPC500; S9300, Quidway S5300, and S5300 routers with software before V200R007C00; and S5700 routers with software before V200R007C00SPC500 makes it easier for remote authenticated administrators to obtain encryption keys and ciphertext passwords via vectors related to key storage. |
| OpenSSL before 0.9.8za, 1.0.0 before 1.0.0m, and 1.0.1 before 1.0.1h does not properly restrict processing of ChangeCipherSpec messages, which allows man-in-the-middle attackers to trigger use of a zero-length master key in certain OpenSSL-to-OpenSSL communications, and consequently hijack sessions or obtain sensitive information, via a crafted TLS handshake, aka the "CCS Injection" vulnerability. |